Installation Manual
H3C SecPath F100-C-EI Firewall
Chapter 6 Troubleshooting
6-2
I. No terminal display
Symptom:
The console terminal does not display any information after
POST of the firewall.
Troubleshooting:
1) Check that:
z The power system is correctly working.
z The Console cable is connected correctly.
2) If you cannot locate the problem yet, check the console
cable and the parameter settings of the terminal (for
example, HyperTerminal).
II. Illegible terminal display
Symptom:
The console terminal displays illegible characters after the POST
of the firewall.
Troubleshooting:
Verify that the baud rate is set to 9600, data bit to 8, stop bit to 1,
parity to none, flow control to none, and terminal emulation to VT100
or auto-detect. If the parameters do not match the above values,
please reconfigure them.