Installation Manual
H3C SecPath F100-C-EI Firewall
Chapter 3 Installing the Firewall
3-2
3.2 Installing the F100-C-EI
The F100-C-EI can be installed either in a standard 19-inch rack
or on a workbench.
3.2.1 Installing the Firewall on a Workbench
If you do not have a standard 19-inch rack, you can install your
device on a workbench. To prevent any damage, observe the
following:
z Make sure that the length and width of the workbench are
enough to hold the firewall chassis.
z Make sure that the workbench is stable and grounded well.
z Make sure that the workstation is sturdy enough to support
the weight of the firewall and installation accessories.
z Reserve at least 10 cm of clearance around the firewall for
heat dissipation.
z Do not place any object on the firewall chassis to avoid
damaging the device and lowering the heat dissipation.
3.2.2 Installing the Firewall in a Rack
I. Install mounting brackets on the firewall
1) Mounting bracket structure
Figure 3-2 Mounting bracket structure