39
Fan 1 State: Normal
Fan 2 State: Normal
Fan 3 State: Normal
Fan 4 State: Normal
Table 10 Command output
Field Descri
p
tion
Fan 1 Number of the fan.
State
Fan state:
Normal—The fan is operating correctly.
Absent—The fan is not in position.
Fault—The fan has failed.
Displaying the operating state of a power module
Use the display power command to display the operating state of a power module.
<H3C>display power
Power 1 State: Normal
Power 2 State: Absent
Table 11 Command output
Field Descri
p
tion
Power 1, 2 Number of the power module.
State
Power module state:
Normal—The power module is operating correctly.
Absent—The power module is not in position.
Fault—The power module has failed.
Configuring the exception handling method
Configuration procedure
You can configure the device to handle system exceptions (such as system instruction faults, invalid
addresses, data overflow, null pointers, and division by zero operations) by using one of the following
methods:
RebootThe device automatically reboots to recover from the error condition.
Maintain—The device stays in the error condition so you can collect complete data for diagnosis,
including error messages. You must manually reboot the device.
To configure the exception handling method:
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A