Logging in to the access controller module
NOTE:
Because the LSWM1WCM10 and LSWM1WCM20 do not have console ports, you can only redirect to
them from switches.
Logging in to the access controller module directly
When the first connection method described in “Setting up a configuration environment” is used, the
serial port of the PC is connected to the console port of the access controller module and you can directly
log in to the access controller module through the HyperTerminal on the PC.
Redirecting to the access controller module from the switch
Before you redirect to an access controller module from the switch, make sure the AUX port on the access
controller module is in none authentication mode, which is the factory defaults. For how to configure an
AUX port in none authentication mode, see
Table 3.
Table 3 Configure the AUX port in none authentication mode
To do… Use the command… Remarks
Enter AUX port user interface view
user-interface aux first-number
[ last-number ]
Configure the AUX port in none
authentication mode
authentication-mode none
Optional
By default, the authentication
mode for an AUX port is none.
Set the command level for the user
to access
user privilege level level
Optional
Level 3 by default.
When the second connection method described in “Setting up a configuration environment” is used, the
serial port of the PC is connected to the console port of the switch. After logging in to the switch through
the HyperTerminal, you can redirect to the access controller module from the switch by performing the
following operations.
After you redirect to the operating system of the access controller module from the switch, the displayed
interface is switched from the CLI of the switch to the operation interface of the access controller module,
so that you can manage the access controller module.
After the interface switchover, you can return to the CLI of the switch by pressing Ctrl+K.
Table 4 Redirect to the access controller module from the switch
To do… Use the command… Remarks
Redirect to the access controller
module from an S7500E switch
oap connect slot slot-number
Required
Available in user view of the
switch
Redirect to the access controller
module from an S5800 switch
oap connect slot slot-number system
system-name
Required
Available in user view of the
switch