Visual Panel Designer User Manual Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com Manual Version: 5PW100-20150427 Product Vers
2-3 Figure 2-3 License agreement Read the license agreement carefully. Click I accept the terms of the License Agreement to proceed.
2-4 Figure 2-4 Choose install folder Select an installation folder and then click Next to enter the pre-installation summary window.
2-5 Figure 2-5 Pre-installation summary Click Install to enter the installing VPD window.
2-6 Figure 2-6 Installing Visual Panel Designer Wait until the installation is complete.
2-7 Figure 2-7 Install complete Click Done.
3-1 3 H3C VPD Uninstallation Select Start > All Programs > H3C Visual Panel Designer > Uninstall Visual Panel Designer. The VPD uninstall w
3-2 Figure 3-2 Uninstalling VPD Wait until uninstallation is complete.
3-3 Figure 3-3 Uninstallation complete Click Done.
4-1 4 H3C VPD Quick Start H3C VPD Overview Figure 4-1 H3C VPD interface Toolbar: Provides the commonly used buttons listed as follows. New Proje
4-2 Import Project: Imports a project in a zip package to the VPD. SNMP Configuration: Configures the MIB definition. The system interacts with th
Copyright © 2010-2015, Hangzhou H3C Technologies Co., Ltd. and its licensors All Rights Reserved No part of this manual may be reproduced or transmi
4-3 z Add Fan: Adds a fan. z Add Power Supply: Adds a power supply. z Add Other Entity: Customizes an entity. z Batch Add: Adds entities i
4-4 z The panel management page displays the enterprise IDs and names of the existing projects in iMC. You can import to the iMC a project exported
5-1 5 H3C VPD Configuration Guide Figure 5-1 Operation flow VPDAdd chassisView the device MIB informationAdd module/power supply/fanAdd port/other e
5-2 z Enterprise ID: Unique identifier for a vendor’s device. For example, the enterprise ID of an HP device is 11 and that of an H3C device is 2550
5-3 Figure 5-2 S7503E in the device panel tree In the property column of a physical entity, as shown in Figure 5-3, MIB Table indicates where the s
5-4 supply entity in the device’s slot 1 exists and where the entity is read. Entity Status indicates the status rule of the entity in the device’s l
5-5 SNMP Configuration 1) Click the icon in the toolbar (or press the shortcut key Ctrl+M) to enter the SNMP configuration page. The SNMP configura
5-6 Figure 5-6 Create SNMP table 3) Click Next to display the Entity Index tab. An entity index is usually unique in the MIB table. MIB Node Name i
5-7 Figure 5-7 Entity Index tab 4) Select the Description tab. The description of an entity is displayed when you place the cursor over the entity
5-8 Figure 5-8 Description tab 5) Select the Vendor Type tab. The vendor type is unique to each entity.
i Table of Contents About This Manual...iii 1 H3C VPD System Overvie
5-9 Figure 5-9 Vendor Type tab 6) Select the Relative Position tab. Relative position indicates the sequence of the entity on its parent entity.
5-10 Figure 5-10 Relative Position tab 7) Select the Parent Entity Index tab. The parent entity index refers to the index of the current entity’s
5-11 Figure 5-11 Parent Entity Index tab 8) Select the Class tab. Entity class refers to the type of the entity, such as chassis, module, and port
5-12 Figure 5-12 Class tab 9) Select the Other tab. Other provides an option for you to create a node other than the above five nodes predefined i
5-13 Figure 5-13 Other tab 10) Click Next to enter the Index List page. You can arrange indexed nodes on this page to determine the sequence of th
5-14 Figure 5-14 Index List page 11) Click OK. 12) You can right-click a table name from the SNMP configuration tree to modify or delete the table
5-15 Figure 5-15 Status configuration page 2) When configuring more than one nodes for a common status, separate the node names with semicolons. T
5-16 Figure 5-17 Complete portCommonStatus rule 4) A combo status comprises of multiple common statuses. The following figure shows a combo sta
5-17 Figure 5-18 Combo status rule Figure 5-19 PortRj45Status rule
5-18 Uploading Images The Entity Image property allows you to upload the entity image by clicking the … button. Figure 5-20 Entity image property
ii H3C S12518-S12508 IRF Virtual Device...6-10 7 FAQ ...
5-19 Figure 5-21 Upload images Compiling a MIB Select Tools > MIB Compiler to compile a MIB. Operation instruction: MIB compiling depends on cer
5-20 Figure 5-22 Compile a MIB Exporting a Project Shortcut key: Ctrl+E Select Project > Export Project to export a project. Operation instructi
5-21 Figure 5-23 Import a project Configuring the Project Property Shortcut key: Ctrl+P Select Project > Project Property to configure the proje
5-22 Figure 5-24 Configure the project property Finding Entities Shortcut key: Ctrl+F Select Edit > Find to enter the Search page. Operation ins
5-23 Using VPD Projects in the iMC This section describes the operations in the iMC. Suppose you have logged in to the iMC as an administrator. VPD M
6-1 6 H3C VPD Examples HP ProCurve J9019A Switch 2510-24 The H3C VPD provides a simple support scheme for general low-end devices. The following tak
6-2 Figure 6-2 Create HP project 3) Right-click Chassis from the Device Panel Tree and click Add to add a device. 4) Edit the value of each proper
6-3 Figure 6-4 Select the entity image 5) Select device 2510_24 from the device panel tree. The device image appears at the preview area. Drag the
6-4 Figure 6-5 Add ports in a batch 7) Drag the ports together to the right places on the panel. In this example, there is a gap between the first
6-5 Figure 6-7 Set the vendor type in a batch If you do not set the vendor type of a port, the system reads the vendor type value from the device
iii About This Manual Organization Visual Panel Designer User Manual is organized as follows: Chapter Contents 1 H3C VPD System Overview Introduces
6-6 Figure 6-8 Rotate ports in a batch 10) Add Combo port 25: first click the Add Port icon () to add the electrical port. Drag it to the right pl
6-7 Figure 6-9 Add the electrical port of Combo port 25 Figure 6-10 Add the optical port of Combo port 25 11) Add Combo port 26 in the same way.
6-8 14) Select Project > Export Project from the menu bar. Select the export directory, and then click the Select Directory button. The system aut
6-9 Figure 6-12 Device panel management 16) Click Import to enter the page for uploading a project file. Click Browse to select the exported zip pa
6-10 17) Search the device by its IP. Click the operation icon and select Open Device Panel. Right-click the device panel and the system displays th
6-11 virtual device as an example to describe how to configure the device panel for a high-end device by using the H3C VPD. 1) The H3C S12500 series
6-12 MIB management function to view the information. To do so, log in to the iMC and then enter the system management page. Figure 6-17 Table view b
6-13 method allows you to not add the Container entity, which does not exist actually. Figure 6-18 Add a module 8) Add all modules in the same way
6-14 Figure 6-20 Add power supplies and fans 10) Add module entity: right-click Module from the device panel tree and click Add. Set the module en
6-15 Figure 6-22 Add a port 12) Add power supply and fan entities in the same way. Figure 6-23 Add a power supply entity
iv Symbols Convention Description Means a complementary description. Obtaining Documentation You can access the most up-to-date H3C product docum
6-16 Figure 6-24 Add a fan entity 13) Add entities for the S12508 in the same way. Then save and export the project, import the project to the iMC,
6-17 Figure 6-25 S12518 device panel segment
7-1 7 FAQ How Can I Locate Entities Fast? On a device, there may be modules with fixed positions, such as the module in slot 0 shown in Figure 7-1.
7-2 Figure 7-2 Locate entity Figure 7-3 Vendor type of the module When Uploading a New Project Created in VPD, I Was Prompted That the Project Al
7-3 new project are probably different from those of the project in the iMC. Therefore, when you upload the new project to the iMC, the new project a
7-4 time, you need to set the endmatch attribute to 1, meaning to match only the last part of the OID (separated into several parts by dots). On the
7-5 type ethernetCsmacd(6) and gigabitEthernet (117) as defined in the IANAifType-MIB, are added to the project. Figure 7-6 Pre-defined entities for
7-6 z entPhysicalParentRelPos: Relative position (sequence number) of the entity on its parent entity. For example, if an interface module provides
7-7 Description of the nodes: z ifIndex: Index of the table. Many other tables reference the data in the ifTable based on the association with this
7-8 Figure 7-11 Statuses z portCommonStatus: Determined by the ifAdminStatus and ifOperStatus nodes. If their values are both 1, the port is displ
1-1 1 H3C VPD System Overview The H3C Visual Panel Designer (hereinafter referred to as H3C VPD) allows you to custom the device panel information d
7-9 port and optical port. To use the status rule, set the same relative position for the two ports of the combo port (that means only one port is en
2-1 2 H3C VPD Installation z Software installation CD (shipped in the product package) This CD comprises the installation program, and the H3C VPD
2-2 Figure 2-2 Introduction Click Next to enter the license agreement window.
Commentaires sur ces manuels